Grundig Alkaline
| Other measured values: |
Effective capacity of the battery by voltage 0,8V is 1.315 Ah Maximum capacity of the battery by voltage 0,1V is 1.396 Ah |
Table of measured values of the discharging current 130 mA
| Time | 00:00 | 00:40 | 01:30 | 02:20 | 03:10 | 04:00 | 04:50 | 05:40 | 06:30 | 07:10 | 08:00 | 08:50 | 09:49 |
| Volts | 1.341 | 1.201 | 1.141 | 1.092 | 1.067 | 1.057 | 1.037 | 1.02 | 0.995 | 0.968 | 0.919 | 0.743 | 0.101 |
| Amps | 0.18 | 0.17 | 0.16 | 0.15 | 0.14 | 0.15 | 0.14 | 0.15 | 0.15 | 0.14 | 0.14 | 0.12 | 0.06 |
| Watts | 0.241 | 0.204 | 0.183 | 0.164 | 0.149 | 0.159 | 0.145 | 0.153 | 0.149 | 0.136 | 0.129 | 0.089 | 0.006 |
| AmpHrs | 0.003 | 0.12 | 0.256 | 0.384 | 0.511 | 0.638 | 0.759 | 0.879 | 1.003 | 1.099 | 1.215 | 1.327 | 1.396 |
| WattHrs | 0.004 | 0.151 | 0.309 | 0.452 | 0.59 | 0.724 | 0.851 | 0.975 | 1.099 | 1.194 | 1.304 | 1.4 | 1.416 |